Dongling MonitoringIntegrated Testing / Sensing / Monitoring
DL-WM-103

Wireless Static Strain Acquisition System

Wireless static strain acquisition system for structures where cabling is difficult, supporting full-bridge, half-bridge, two-wire and three-wire quarter-bridge strain inputs, bridge-type sensors, voltage signals, ZigBee communication, 8 points per module, up to 256 points per computer, and 20 Hz per-point sampling.

DL-WM-103 Wireless Static Strain Acquisition System

System Category

DL-WM

Signal Type

Wireless static strain

Communication

ZigBee wireless network

Product Image and Application Context

Visual reference for Wireless Static Strain Acquisition System

Product images are used when available for RFQ evaluation and product recognition.

Primary Product Image

DL-WM-103 Primary Product Image

Product image configured for this product.

Bridge

Typical distributed strain module installation deployment for project configuration.

Building

Typical distributed strain module installation deployment for project configuration.

Civil

Typical distributed strain module installation deployment for project configuration.

Technical Specifications

Category

DL-WM

Measurement Range

Full-bridge, half-bridge, and quarter-bridge strain inputs

Sampling Rate

20 Hz per measurement point

Communication Protocol

ZigBee wireless network

Protection Level

Field enclosure required by project

Power Supply

Battery operation

Application Tags

Bridge, Building, Civil, Mechanical

Installation Type

Distributed strain module installation

Engineering Applications

Where this DL product is applied

Wireless strain acquisition supports large structures with scattered measurement points.

Each module supports 8 points, with system expansion up to 32 modules and 256 points per computer.

Supports bridge-type sensors, voltage inputs, on-device cache, and battery operation.

Technical basis may reference GB/T 6587 environmental and electronic equipment requirements.

Typical Use Cases

Typical monitoring use cases

Bridge, civil, and mechanical structural strength tests where wiring is difficult.

Static strain monitoring with distributed measurement points and moderate sampling requirements.

System Integration Context

Sensor, DAQ, and software context

Confirm bridge type, strain gauge resistance, module count, wireless coverage, and test duration.

Plan gateway position and battery maintenance for multi-module ZigBee networks.

Keep GB/T 6587 references where environmental test class documentation is required.